Spectrophotometer

UV-Vis/NIR

  • Double beam spectrophotometer
  • Operation by iPad (optional)
  • Wavelength range 190-1100 nm
  • Baseline stability 0.0005 Abs/h (260 nm after 2 hrs warm up period)
  • Longlife Xenon flash lamp with 7 years warranty
  • Automatic 6-cell turret
  • Wide range of accessories to support various application

  • Ratio beam spectrophotometer
  • Baselie stability 0.007 Abs/h (260 nm 2 hrs after power on)
  • Longlife Xenon flash lamp
  • Equipped automatic 6-cell turret

  • Double beam spectrophotometer
  • 26.4 cm color LCD
  • Baseline stability 0.0003 Abs/h (500 nm 2 hrs after power on)
  • W1 and D2 lamps
  • Diverse optional accessories for specific application

  • UV-Vis spectrophotometer
  • Low stray light and low noise
  • Single or double monochromator
  • Wavelength range 190-900 nm
  • Baseline stability 0,0002 Abs/h (500 nm 2 hrs after power on)
  • Broad range of accessories to facilitate any application
  • UV-Vis/NIR spectrophotometer
  • For solid, liquid, and large sample
  • Low stray light and low polarization
  • Prism grating optical system
  • Setting wavelength range 175-3300 nm
  • Wavelength accuracy UV-Vis 0.2 nm and NIR 0.1 nm
  • Detector: Photomultiplier (UV-Vis) and Cooled PbS (NIR)
  • Light source D2 (UV) and W1 (Vis and NIR)

AAS, FL, and MS

  • Flame/Graphite furnace analytical method
  • Up to 12 element analysis
  • Twin injection function
  • The one and only Polarized Zeeman correction by DC magnetic field
  • Wavelength range 190-900 nm
  • Detector photomultiplier

  • Best-in-class analytical signal-to-noise
  • Highest detection sensitivity
    • F-7000 S/N > 800 (RMS); S/N> 250 (Peak to Peak)
    • F-7100 S/N > 1200 (RMS); S/N > 360 (Peak to Peak)
  • Wavelength measurement range 200-750 nm
  • Wavelength accuracy 1 nm
  • Light source Xenon lamp

  • Compact with standard operating panel
  • Accurate zero-point correction function
  • Highest detection sensitivity (S/N 800 or above)
  • Wavelength measurement 220-730 nm
  • Wavelength accuracy 3 nm
  • Light source Xenon lamp

  • Higher reliability for analytical results through mass detection
  • Measurement mass range 20-1000 Hz
  • Ion source electrospray ionization

Chromatography

  • GUI controller with touch panel
  • New pump with pressure up to 60 MPa
  • Carryover < 0.003% (Cut method)
  • Unique preheat column oven system
  • Detector
    • UV-Vis (Wavelength 190-600/900 nm; accuracy 1 nm)
    • Diode Array (Wavelength 190-200 nm; accuracy 1 nm)
    • Fluorescence (Ex. wavelength 200-850 nm; Em wavelength 250-900 nm;

  • Simple design and user friendly layout
  • Leak sensors in all modules
  • Detector
    • UV (Wavelength 190-600 nm; accuracy 1 nm)
    • Diode Array (Wavelength 190-900 nm; accuracy 1 nm)

  • Highest pressure system 140 MPa, 1400 Bar
  • Achieve 90% reduction in analysis time
  • Detector
    • UV-Vis (Wavelength 190-900 nm; accuracy 1 nm)
    • Fluorescence (Wavelength Ex. 200-850 nm, Em. 250-900 nm; accuracy 3 nm)
    • Diode Array (Wavelength 190-650 nm; accuracy 1 nm)

  • Benchtop or floorstanding design
  • Use highly reliable and stable post-column nihydrin method
  • Detection limit of 2.5 pmol (S/N 2, Asp)
  • 30 min of analysis time
  • Spectrophotometer wavelength 570 nm, 440 nm

Centrifuge

General Purpose

  • Compact design
  • Max speed 6,000 rpm
  • Max capacity 2,000 ml {500ml x 4 tubes) {CT-6EL)
  • Speed control range 300-6,000 rpm
  • Timer 1-99 min with HOLD

  • Compact tabletop design
  • Autoclaveable rotor
  • Max speed 15,000 rpm
  • Max capacity 2ml x 24 or 0.5ml x 24 {T15A62 angle rotor)
  • Speed control range 300-15,000 rpm
  • Temp control range -20-40°C {CT-15RE)
  • Timer 1-99 min with HOLD

  • Max speed 16,000 rpm {CF-16RN)
  • Max capacity 1 L {250ml x 4: T5SS31 rotor) {CF-16RN)
  • Speed setting range 300-16,000 rpm {CF-16RN)
  • Timer 5-55 sec/1 -99 min with HOLD
  • Temp setting range -9-40°C

  • Max speed 4,800 rpm
  • Max nominal capacity 2,000 ml {500 ml x 4)
  • Temp setting range -9-40°C
  • Timer 5-55 sec/1-99 min with HOLD

Refrigerated

  • Self-locking rotor system
  • Non-contact imbalance detection
  • Economy mode (auto standby function)
  • Max speed 22,000 rpm
  • Max capacity 1,500 ml x 4 bottles
  • Temp control range -20-40°C
  • Upgradeable for contious flow rotor

  • Automatic standby function
  • USB interface
  • Max speed 7,000 rom
  • Max nominal capacity 6,000 ml
  • Temp set range -20-40°C
  • Timer set range (with HOLD)
    • (min:sec) 1 sec-99 min 59 sec
    • (hrs:min) 1 min-99 hrs 59 min

  • All rotors maintained at 4°C at maximum rotor speed
  • 1100,000 x g swing/angle rotors
  • Max speed 30,000 rpm
  • Max capacity 6 L
  • Temp set range -20-+ 40°C

Ultra Centrifuge

  • Max speed 80,000, 90,000, or 100,000 rpm
  • Max actual capacity 210/225ml x 6 bottle (P21 A2 Fixed angle rotor)

  • Max speed 120,000 or 150,000 rpm
  • Max capacity 30ml x 6 tubes or 7ml x 4 tubes (swing rotor)

  • Max speed 150,000 rpm
  • Max tube capacity 30 ml x 6 tubes or 7 ml x 4 tubes (swing rotor)

Other

  • Blood cell washing centrifuge
  • 4-stage display:
    WASH, CENTRIFUGE, DECANT, and AGITATE
  • Capacity 24 test tube size samples
  • Speed 1,200 or 3,000 rpm
  • Timer 1-99 sec

  • Continous flow centrifuge
  • Able to purify large-volume corpuscle sample such as vaccines and other pharmaceutical product
  • Max speed 40000 rpm
  • Speed control accuracy 100 rpm
  • Rotor temperature accuracy 2 C (0-40 C)
  • Oil rotary vacuum pump system